2. For house of grade 1,2,3 : wiring is embedded in wall, in floor :
Type of electric line |
Scope of application |
CADIVI’s cable should be used |
|
From the CB box of power company or the pole outdoor to the service entrance head |
One phase : Duplex cable (Du-Cv,Du-CX)
|
From service entrance head to the meter |
One phase :Service Entrance cable two cores
(DK-CVV , DK-CXV) |
|
From the meter to : electric lamp, water pump, electric appliances ( Television, ceiling fan, wall-fan, …) |
VC wire
Nonsheath cable (CV or CX)
Oval sheathed cord or flat sheathed cord with nominal area above 4mm2 (VCmo, VC mod)
|
Use for the strip cords or multi-purpose extension cords |
Flat nonsheathed cord VCmd
Oval sheathed cord VCmo
Flat sheathed cord VCmod |
| Notes : In case the installed length of wires and cables are over 200m, the voltage drop is too high, it’s necessary to choose a big enough conductor size, so that voltage is not less than 210V |
|