Method of selection of wire and cable according to part III.2 :

line Wires used for neon light 1,2m-40W , bulb light 100W or ceiling fan are VC1 (F12/10 ) or CV1 - 750V or CX1 -0,6/1kV   
 Wires used for wiring of socket that for television, video cassette recorder (VCR) and standard fan are VC2 (F16/10 ) or                                                 CV 2 – 750V or CX 2 -0,6/1kV     Wires used for wiring of socket that for air-conditioner, washing-machine, electric-stove, electric-iron are VC3 (F20/10) or CV3 – 750V or CX 2,5 -0,6/1kV   
 Wires and cable used for water pump 3HP are VC5 (F26/10 ) or                                    CV 5,5 - 750V or CX 4 -0,6/1kV  
Distribution -line Distribution line for ground floor will have total of installation power is : 720W + 2900W + 400W + 1125W + 450W = 5595W. VC7 (F30/10 ) or CV6 - 750V or CX5,5 -0,6/1kV are selected     
Distribution line for upper floor will have total of installation power : 840W + 1750W + 225W +4500W = 7315W. VC7 (F30/10 ) or CV8 - 750V or CX6 -0,6/1kV are selected         
Main -line In fact, all electrical appliances are not used at the same time so power consumption is from 50% to 80% of power installation .
Main line for this house that will have total of installation power : 5595W +7315W = 12910W. Select the factor of power is 0.7, then total of consumption power is  9000W DK-CVV-2x10-0,6/1kV or DK-CXV-2x10-0,6/1kV or Du-CV-2x10-0,6/1kV or Du-CX-2x10-0,6/1kV are selected     

 

 
Page: 1  2  3  4  5  6  7  8  9  10  11  12
Introduction | Products | Members of CADIVI | Distribution network | News | Contact us
 
© 2006 Vietnam Electric Cable Corporation (CADIVI).
Head office: 70-72 Nam Ky Khoi Nghia St., 1st District, Ho Chi Minh City.
Tel: (84.8) 3829 9443 - 3829 2971 - 3829 2972. Fax: (84.8) 3829 9437. Email: cadivi@cadivi.com.vn